Included air conditioner: how do you use its energy label when comparing flats?
Identify the unit that will stay, match its model to the official label record, and compare capacity with rated electricity use. Check condition and handover terms separately.

Start with the unit that will actually stay
If a flat is offered with air conditioning, identify each indoor and outdoor unit that is included in the handover before comparing energy labels. Ask the owner or agent for the brand, exact model designation and a clear photograph of the label or nameplate. A listing photograph may show a machine that will be removed, while a replacement promised verbally may be a different model. Record which room each machine serves and whether the tenancy or purchase documents include it. This makes the energy question specific: what will this particular home contain on the day you take possession?
A label can help compare the rated performance of identified products; it cannot certify a used machine's current mechanical condition, cleanliness, installation quality or suitability for a particular room. During a viewing, ask permission to operate the machine briefly, observe whether cooling begins and note unusual noise, water dripping or damaged controls. Do not treat a short demonstration as a full service test. If the unit matters to the deal, request recent maintenance and repair records and agree how any defect discovered before handover will be dealt with.
Read the label as several separate measurements
The Electrical and Mechanical Services Department explains that the cooling grade runs from Grade 1, the most efficient, to Grade 5, the least efficient within the relevant label system. The same label gives annual cooling electricity consumption in kilowatt hours and cooling capacity at full load. These are different quantities: a machine can use more electricity because it provides more cooling. A lower annual consumption figure is informative only when the candidate machines have a useful and broadly comparable cooling capacity and are assessed under the same standard.
Copy the model and reference number as well as the grade. EMSD defines the reference number as the number assigned to a specific product model. It defines cooling seasonal performance factor as cooling delivered during the assumed season divided by energy consumed in that period. A higher factor indicates better rated seasonal efficiency; it does not predict your household's exact bill. For a reverse cycle model, read the heating fields separately. The cooling grade is not a statement about heating performance, and the annual cooling and heating figures should not be combined without explaining the intended use.
Match the model instead of relying on a sticker colour
If the label is faded, missing or partly hidden by cabinetry, do not guess its grade from the machine's appearance. Ask for a photograph of the model plate and look up the same brand and complete model code in EMSD's listed-model records. Indoor and outdoor components of a split system may be identified together; an abbreviated sales name can lead to the wrong entry. The register carries the model, reference number, cooling grade, annual consumption, capacity and seasonal performance factor. Keep a dated copy of the entry you used, because a later search may show changed supply status or a revised record.
A label or database result belongs to a model, not automatically to the particular installed machine in the flat. Check that the recorded code matches what is present and that the proposed handover schedule names that unit. If the model cannot be identified, mark its energy performance as unknown rather than assigning a grade from a similar product. For a renter, that uncertainty may affect a request for replacement or a lower all-in housing budget. For a buyer, it may change the amount reserved for eventual replacement; it does not by itself establish the cost of replacing the machine.
Keep grade, capacity and room use together
First decide what comfort the room needs. A large west-facing living room, a small bedroom and a room that receives cooking heat pose different cooling loads. A viewer cannot establish the correct capacity from floor area alone; glazing, sun exposure, ventilation, insulation and how many people use the room also matter. Ask the installer or a suitably competent supplier to assess capacity if replacement is contemplated. A very efficient model with insufficient cooling output is not a sensible solution just because its grade looks attractive.
Compare models in a small worksheet: room served, full model code, cooling capacity, cooling grade, annual cooling consumption, seasonal factor, condition, and whether the unit is included. Keep the capacity and consumption columns side by side. If one candidate has a much larger machine, its annual figure is not a like-for-like operating-cost comparison. Conversely, a similar capacity with a materially different annual figure may justify asking why, and whether the label uses the same grading method. A useful comparison explains these differences rather than reducing the decision to a single coloured bar.
Where a flat includes several machines, list them room by room instead of adding their label figures into a promised household bill. The annual test assumptions do not say every machine will run for the same hours in your home. A household that cools only a bedroom at night may value the bedroom machine more than a rarely used living-room unit. Mark which unit carries the decision, then compare its capacity and condition first.
Use the annual figure as a scenario, not a promised bill
EMSD describes annual electricity consumption as a value for comparing models and estimating possible savings. It is calculated under the label's standard assumptions. Your actual use depends on operating hours, thermostat setting, weather, maintenance, occupancy and the electricity tariff that applies to the address. To budget, take the difference between comparable annual cooling figures and multiply it by a tariff that you have checked with the electricity supplier for your own situation. Keep the tariff date and any applicable fuel adjustment or other charge visible. Do not present the result as a guaranteed saving or as the flat's whole electricity bill.
A worked decision can be made without inventing a current tariff. Suppose two flats have similarly sized bedrooms and their included machines have verified, comparable label records. Flat A's machine shows lower annual cooling consumption but has a noisy fan and no maintenance record. Flat B's machine shows higher rated consumption but has a documented recent service and a handover promise that it works. The label makes the running-cost question clearer; the viewing and documents answer a different question about current condition. Ask for a written repair or replacement arrangement for A before treating its better label as a practical advantage.
Check age and grading context
An older label may have been issued under an earlier grading standard. EMSD's records distinguish listed models and historical grading groups, so two stickers with the same grade may not represent the same test threshold. The reference number and year help locate the correct record. When one candidate is old and the other current, compare the published capacity, annual cooling use and seasonal factor with their definitions in mind. If the figures were generated under different methods, describe that limitation and request current product advice instead of making a precise saving claim from unlike labels.
The year on the energy record is not necessarily the year the machine was installed in the flat. Ask for an installation invoice or maintenance record if remaining service life is important. A freshly painted room does not establish that the air conditioner is new; likewise, an older machine is not necessarily defective. Photograph only the plate and visible condition with permission. Keep brand and model evidence separate from the owner's claim about age, repair or ownership so each can be checked before the agreement is signed.
Turn the comparison into a handover condition
For a tenancy, identify the included machines in the inventory and record their operating state at key handover. Agree in writing who maintains, repairs or replaces them, and what happens if an included unit fails before occupation. Do not assume the energy label allocates maintenance responsibility; that comes from the actual agreement. A tenant who pays the electricity bill may still find a reliable, correctly sized machine more valuable than a nominally higher grade unit that cannot cool the room. Preserve a dated request to the landlord where an issue needs resolution.
For a purchase, distinguish fixtures that will remain from appliances the seller may take. A lawyer or agent can carry a clear appliance schedule into the sale documents. If you intend to replace a unit after completion, check the building's installation rules, the external unit's permitted location and any work needed at the fixed electrical connection before pricing the plan. An advertised efficient replacement should be identified by model or a measurable specification, not an open-ended promise. Before signing, decide whether the current unit is acceptable, whether a documented repair is needed, or whether you are budgeting a replacement.
Make a final comparison that reflects the home
Lay the evidence for each flat on one page: included unit, exact model, matched EMSD entry, relevant room, condition seen, documents requested and the unresolved question. A missing label calls for identification; a poor grade calls for a running-cost comparison; water leakage or electrical irregularity calls for appropriate inspection. These are different responses. Do not operate a suspect or damaged unit repeatedly just to finish a viewing. If the owner cannot resolve a material fault, decide whether the home still meets your requirements under a documented handover condition.
Houseline can help you compare available homes and arrange a further viewing, but a listing is an invitation to verify the actual unit and terms. Use the [Houseline property catalogue](/en/) to shortlist homes with layouts that suit your cooling needs, then carry this worksheet to the viewing. The answer is strongest when the model record, physical condition and agreement all refer to the same machine. Recheck those three points before you pay a deposit or commit to a purchase.