Leasing a fitted office? Walk the escape route before signing

Trace the route from each room to the ground-floor exit, compare the fit-out with approved records, and allocate work on doors, locks and obstructions before occupation.

Houseline editorial team · Last updated
Office desks and a glass meeting room in a Hong Kong commercial unit

Walk the route before you price the office

A fitted office can have attractive desks and meeting rooms yet leave staff uncertain how to reach a safe staircase. Before agreeing rent, walk from the furthest work area and every enclosed room to each available exit, then continue along the common corridor, staircase and ground-floor discharge. Record doors, signs, stored goods, locks, changes of level and any point where the route depends on someone unlocking another tenant's space. The Fire Services Department tells building occupants to know their escape routes, keep corridors and staircases free of obstruction, keep smoke-stop doors closed and ensure exit doors are not locked. A viewing photograph of the lobby is not an escape survey.

Do this during the hours the team will actually use the space. Ask management whether a staircase or exit is ever controlled after normal office hours and how an occupant can open it from the escape side. If a door is obstructed or cannot be opened safely, do not assume the building's age makes it acceptable. Have the manager identify the approved arrangement and rectify a present hazard before occupation. The tenant's immediate decision is whether people can get out through the actual route, not whether a marketing floor plan shows a pleasing pair of arrows.

FSD: fire escape routes and doors

Compare the fitted plan with approved records

The Buildings Department treats means of escape and fire resisting construction as core building-safety provisions. Its public BRAVO service allows registered users to inspect building and minor works records for private buildings; the approved plans can show the original exits, partitions and protected areas. Ask the landlord for the latest relevant approved plan and the history of the fit-out. Mark the current partitions, meeting rooms, server room and reception on a copy. If a wall or door has shifted, ask what approval or minor-works record supports the change. A landlord's assertion that the layout has been used for years is not a substitute for identifying the permitted configuration.

Records need interpretation. A plan may be old, later approved changes may exist, and not every desk position is a building work. A building professional should assess a material discrepancy, especially where an altered partition narrows a corridor or changes how a room reaches an exit. Avoid setting a universal travel-distance rule from a generic diagram; the applicable code depends on the building and use. The Buildings Department lists modification of means of escape among alteration and addition works and advises consulting building professionals and using the required approval route. Put the evidence gap on the leasing checklist rather than declaring the office compliant from a brief tour.

BD: BRAVO building records

BD: alteration of escape routes

Understand doors, locks and protected spaces

A fire rated door is part of a protected route, not simply a security accessory. The Buildings Department says unauthorised alteration can reduce a provision's fire-resisting performance. It also says a locking device is generally unacceptable on a fire rated door across a building exit; if a door must resist entry from outside, it should be readily openable from inside without a key, or an electrical lock should release automatically on power failure. Ask management to demonstrate the actual arrangement without defeating the device. Check for wedges holding smoke-stop doors open, missing closers and storage that prevents a door closing fully.

Do not try to certify fire rating by looking at paint or a sticker. Ask the landlord and management for the door schedule or maintenance record, then have an authorised person assess suspected changes. The same distinction applies to a glass partition: it may look substantial while failing to form the approved fire separation. If the fitted office includes a private entrance that bypasses the common corridor, trace where it leads and whether that access is part of an approved escape arrangement. An exit sign is helpful only if the route behind it is actually available.

BD: fire doors and exit locks

Separate landlord, manager and tenant responsibilities

A leasing agreement should identify who maintains common staircases, fire doors, alarm equipment and the tenant's own fitted partitions. The building manager may hold inspection and maintenance records for common fire service installations, while the landlord may have records for the fitted unit. Ask for the latest available records and any outstanding defects relevant to the route; a dated certificate describes the inspection scope and date, not a promise that the corridor will remain clear forever. Agree who will clear present obstructions and who has authority to alter doors or partitions. A tenant should not promise to repair common property by itself without access and consent.

If the team intends to add meeting rooms, high storage or access-control doors, put that proposed fit-out on a separate plan before treating the existing layout as a precedent. The Buildings Department identifies changes to means of escape as alteration and addition work that may need formal scrutiny. Ask an appropriate building professional to check whether the proposed works affect exit capacity, protected corridors or fire resisting construction. Obtain the landlord's and management's consent where needed, together with any statutory approval, before building. A cheap fit-out quote that omits these steps may shift the cost and delay to the tenant after the lease starts.

Ask about the intended use and people

A space marketed as an office may be intended for very different activity: a few desk workers, scheduled client meetings, classes or events. Do not assume the same layout accommodates every pattern safely. Tell the landlord and building professional how many people are expected, which rooms will be occupied, whether visitors know the building, and when the office operates. Ask whether the proposed use is compatible with the approved building use, government lease, deed of mutual covenant and any licence requirements. The Buildings Department warns that changes of use and structural or fire-safety implications need professional review. This article does not certify a particular occupancy figure or licence.

For the staff, include someone who uses a walking aid, a visitor unfamiliar with the floor and a person working late when reviewing the route. Mark a meeting point and the management contact. The Fire Services Department advises occupants to familiarise themselves with the escape routes and take part in drills. In a fire, staff should use stairs rather than lifts and call 999 when safe. These are emergency practices, not a replacement for securing a lawful and usable route before signing the lease.

BD: alteration and addition works

FSD: fire escape practice

Work through two hypothetical offices

Office A has a lower quoted rent and a fitted meeting room at the back. During a visit, stacked cartons narrow the common corridor; the rear exit has a key-operated lock, and the landlord cannot provide a plan for a recently built partition. Office B costs more in this hypothetical comparison but has a route the team can walk, records for its current layout and a written manager contact for faults. The price difference is intentionally unspecified. The first office needs a professional answer about the partition and an actual correction of the lock and obstruction; a promise to “sort it after signing” does not put those works into the landlord's schedule.

Suppose the team wants to install another private room in Office B. Its present route may be acceptable, but the proposed change still needs review; the tenant should not infer approval for a future partition from evidence for the existing one. Ask the professional to mark the before-and-after route and state what approvals or notifications are required. Compare the total cost and the earliest realistic occupation date only after these answers exist. This method prices the decision the business is actually making, rather than assigning a safety rating from a sales tour.

Turn open questions into lease conditions

Before paying a substantial deposit, compile a short evidence pack: current fitted plan, relevant approved records, written explanation of discrepancies, demonstration of each exit, management's obstruction and lock policy, available inspection records and the intended use statement. Have the proposed lease say who will complete identified remedial work, by what date, with what proof, and what happens if occupation cannot safely begin. If the landlord cannot commit to a correction or grant access for inspection, the tenant can continue comparing other offices rather than inheriting an undefined job.

At handover, repeat the walk with the actual fit-out, furniture and access control in place. Photograph only what you are permitted to record, note the date and ask management to close any newly discovered obstruction. Keep the route clear as staff and storage arrive; a valid opening-day inspection does not license later corridor storage. Houseline's property catalogue can help identify alternatives, but the decision about a particular office rests on its own records and observed route. No article or photograph can replace an assessment of the exact building by a competent professional when the plan and the site disagree.

Compare commercial property